PRODUCT
SELECTION GUIDE
In
order to help you select relay correctly, we offer a product
selection flow to refer to.
METHOD
1(EMPHASISE
ON LOAD CAPACITY)
1)Open
the quick selection product catalog(arrange
in load capacity sequence).
2)Select
several products according to contact load and contact style
preliminary.
3)Rid
of the product that doesn’t accord to the shell dimension.
4)Rid
of the product that doesn’t accord to the environment temperature
and vibration character.
Open
relevant product details according to the page of the catalog and
make a choice after comparing.
Please
fill in the order according to the order mark and the quality grade
of the product you selected.
METHOD
1(EMPHASISE
ON SERIES)
1)
Open
the quick selection product catalog(arrange
in series sequence).
2) Select
several products according to the shell dimension preliminary.
3)
Rid
of the product that doesn’t accord to the contact load and contact
style.
4)
According
to method 1 item 4 and
item
5.
CLASSIFICATION
The
relay our company R&D mainly covers:
Electromagnetic
relay:
A
monstabillity relay,the
output reverses to initial state after the stimulation of the coil
retreated.
Latching
relay:A
double constable relay,the
output retains former state after the stimulation of the coil
retreated.
Thermostat:A
temperature sense component,whose
output is controlled by the temperature.
CONTACT
STYLE
Contact
style refer to table 1
TERMS
and TEST
1
ELECTROMAGNETIC RELAY
1.1
TERMS
a)
Stimulation:control
the input variable of relay,such
as electrifying, heating and acceleration and so on.
b)
High
level: rating level, loading capacity exceed 28V,100mA.
c)
Low
level: loading capacity between50mV, 10μA
and 16V., 0mA.
1.2
TEST
1.2.1
TEST PROCEDURE OF OPERATE VALUE, HOLDING VALUE AND RELEASE VALUE
Test
procedure refers to figure 1.According to national military standard
both figure 1a and figure 1b are correct.
2
LATCHING RELAYS
2.1
OPERATING VALUE TEST
Testing
of operating value(
without release value)
can refer to figure 1a as the
shading voltage test. Similarly it also can be tested as figure 2
step function voltage test. Firstly, give the coil 1 (later
stimulation coil)stimulation
and the outputs ought to accord to the circuit diagram. The
operating voltages named self retain voltage. Oppositely, give the
coil 2 stimulation and the operate voltage of coil 2 named reversion
value.
3
THERMOSTATS
3.1
TERMS
3.1.1
TEMPERATURE CHARACTER
a)Operating
temperature: The temperature value that the output of relay changes
with the temperature ascends.
b)Nominal
operating temperature: Nominal value of operate temperature, for
example 50℃±3℃,
50℃
is nominal operating temperature.
c)Operating
temperature deviation: Measured difference value between operating
temperature and nominal operating temperature,
for example 50℃±3℃,
±3℃is
operating temperature deviation.
d)Reversion
temperature: The temperature value that the output changes after the
relay acts according to item a.
e)Temperature
range: difference value between operating temperature and reversion
temperature.
3.2
TEST
There
are three test methods, and the three test methods are all regarded
availability.
a)
Measuring
block test: At the room temperature, place the induce side of
temperature of relay
close
to the measuring block(mostly
copper block)
and no gap, through test
measuring block temperature characters ascertain the temperature
character of the relay.
b)Air
circle test: place the relay in oven that having air circle
circulation
c)
Liquid
test: place the relay in container that having liquid circulation.
The
test results of the three methods are different,often
the difference between air circle test and liquid test is less,compared
to measuring block test the difference is possibly 3℃~5℃。Measuring
block test and air circle test are adopted usually. Otherwise
temperature variety speed has great influence on test. Temperature
variety speed must be controlled rigidly. To assure application
requirement, the user and the supplier should communicate and amend.
ENVIRONMENT
TEMPERATURE
Environment
temperature is not the room temperature but the temperature where
the relay mounted. Environment temperature includes the balance on
radiation of component around and radiation condition.
2
LOAD SWITCHING
ABILITY
Load-carrying
ability of relay is not always from low level to high level,the
relay having no low level parameter cannot be used in low level.
Increasing
the load voltage means decreasing load circuit, which can refer to
load character.
3
LOAD
CHARACTER
Contact
load and life of the relay are operating frequency when the load
serves as resistance under rating voltage current. When the load
character change, the contact parameter will change accordingly,
users can convert load current referring to table 3.
TABLE
3 LOAD CURRENT CONVERSION of DIFFERENT LOAD CHARACTER
|
Resistance
current
|
Inductance
current
|
Electromechanical
Current
|
Light
current
|
|
100%
|
30%
|
20%
|
15%
|
We
suggest increasing contact protection measure for inductance load
and electromechanical load, which can connect series
.resistance-capacitance component parallel The selection of
resistance can according to 0.5Ω/V
to 1Ω/V
every volt and the selection of capacitance can according to 1μf
/ V. Also it can connect diode or restrain diode parallel.
It
would need resistance in series if capacitance serves for load.
Otherwise it will bring fatal damages to relay contacts.
4
TRANSIENT STATE
RESTRAIN
It
will produce several fold negative peak voltage when remove the
stimulation voltage of the coil, which will bring great damage to
the circuit. And it should be restrained. There are many restrain
methods. Commonly connecting diode parallel is most simple and
economy. But connecting diode will prolong release period.
Manufacturer
also supplies relay having transient state restrain function. It is
more convenient. These kinds of coils have polarity. Pay more
attention in application. Polarity connect in reverse can damage
restrain component and lead the relay to invalidation. When testing
the insulation resistance and voltage withstand of these kinds of
relays the coil should short circuit, avoiding mangle the restrain
components.
5
COIL
STIMULATION SELECTION
Stimulation
voltage selection of relay should according to rating, because relay
circumstance, mechanics and electricity capability are tested under
that condition. If the coil operate voltage act as stimulation
voltage, it will bring fatal damage to the relay.
Voltage
pulse width of the latching relay coil should satisfy the
requirement(treble
the operate time ),but
electrifying perennial is unsuitable,and
no more than 15 minute. Because electrifying perennial will make the
coil hot and damaged.
6
CONTACT
PARALLEL
Contact
parallel cannot improve the current load ability, because every
contact team operate is not always synchronization, which lead the
contact to act earlier undertake whole current. But Contact parallel
can improve the reliability of connectedness of relay.
7
SEAL
CHARACTER
Seal
character has great influence on relay application and storage. Good
seal character is favorable for relays working under high sea level.
Welding product instead of tin embedding product is a advisable.
8
THERMOSTAT TEMPERATURE CHARACTER SELECTION
The
temperature character of thermostat is relative to environment,
equipment, parameter and so on. It is important to retain consistent
with the locale condition. It would require further certificate
whether the eligibility product applicable or not. Commonly, you can
select an appropriate temperature character value and find out the
difference through application. Then correspond with supplier and
amend.
9
DERATED
CAPACITY IN SERVICE
Appropriate
derated capacity in service can decrease the invalidation
probability of relay under the rating circuit and increase the life
and reliability of the relay. Advice derated capacity in service at
70 percent of the rating.
APPLICATION
AND MOUNTING
1
The
down lead of sealed relay is glass insulated, and cannot be shaken
random. Otherwise the glass insulated is easily broken. Thereby the
relay seal ability is damaged or leads the down lead to flexible,
rupture or makes the relay invalidation. When need pull the down
lead, please fix the down lead 3-millimeter
close up the motherboard, and the biggish diameter down lead
shouldn’t be shaken.
2
Twisting
the lead with apropos force when welding lead,avoiding
the down lead become flexible. The down lead is easily damaged under
the condition of bonding long, weight and hard lead. After
completing the mounting, fix the long lead, and avoid damaging the
down lead because of the lead swing.
3
The
relay has a varnish-coated layer, if the relay cover requires
grounding, please rid the vanish of bond point. Wedding period
should be very rapid or adopt cooling protection.
4
The
solder of leading of the relay should select neuter solder, avoiding
contaminating glass insulator and reducing insurability. At the same
time long wedding period is not suitable. The wedding temperature is
no more than 260 ℃.
Therefore you can select matching electric iron referring to the
wedding temperature. Moreover wedding period persistence no more
than 3 seconds. Repeat welding after the welding point cooling down
if require. Clear the solder in time.
5
If
the relay falls to the ground inadvertent, the inner component of
the relay is possible injured because of the intensity impact.
Checkout the relay is eligible.
6
The
relay should not support the product itself if the relay directly
mounted on printed circuit board. The down lead,
relay cover and printed circuit board should be embedded
Integrative. Possibly select the relay with installation lug or add
sleeve in addition, avoiding endanger the safety of down lead or
product.
7
When
mount the relays avoiding synchronic cantilever beam, for fear of
transfer energy to relay leading the relay to under syntonic.
Especially printed circuit board is easily syntonic and lead the
relay to invalidation if the rigidity of printed circuit board is
not enough, therefore the rigidity of printed circuit boards should
be strengthen.
8
Relay
color mark: Commonly, the color of glass insulator of one coil down
lead of electromagnetic relay is different from others. For latching
relay, transient state restrains relay and counterbalance relay it
expresses the stimulation positive pole .For latching relay,it
also expresses the positive pole down lead. Attentively, avoid
making you circuit confusion. For electromagnetic relay it is only a
down lead mark and no polarity requirement.
9
To
ensure reliable heat transfer the induce side of temperature of
thermostat mounted close to the control unit, and no gap,
7
ORDER
Once
make a choice of relay, please fill in order contract refer to the
order mark.
8
STORAGE
Optimal
storage condition of packed relays is at-10℃~+40℃,relative
humidity no more than 80 percent, and no acid ,alkali or other
corrosive gas around. |